| Solutions are not in any particular order |
Contactor |
| |
|
|
|
| Problem |
Solutions to assist with repair |
Heater contactor won't engage but heater light is on |
- not wired correctly
- Low voltage
- Bad coil
|
|
Heater contactor won't engage and heater light is off |
- Check pressure switch
- Check thermostat
- Replace contactor
|
|
System contactor won't engage but ready light is on (mostly on DX type) |
- Pressure related problem
- Bad contactor or low voltage
- Short in spaside
|
|
System contactor won't engage and ready is is off (mostly on DX type) |
- Low votage or bad contactor
- Door not closed allowing interlock switch to engage
- Blown fuse
|
|
Contactor chattering |
- Water in spaside
- Bad coil
- Low voltage at contactor
- Wrong contactor installed (undersized)
|
|
Contactor has no power |
- Contactor is bad
- System High limit
- Door interlock not engaged
|
| |
| |
|
|
|
| |
|
|
|
|