Symptom |
Meaning |
Solutions |
Spa Inoperative
Spa Side Inoperative |
Power failure outside of spa.
Spa Side could be locked.
|
Check power source Breaker and GFCI; Reset breaker/GFCI. Call Electrician if it will not start.
If lock icon is visible, unlock by depressing
the “UP” button for 5 seconds |
| If any errors are found, the following replacement messages may be displayed: |
| Message |
|
|
|
| BLO |
Blower Error
|
Check fuse 3 and then verify that the blower motor is plugged in. |
| CP |
HEET pump may be faulty. |
Check that HEET pump is plugged in. |
CS
|
Current Sensor
|
Check that current sensor board is plugged into circuit board. |
| F1 or F2 |
Blown Fuse |
Replace fuse 1 or fuse 2 |
| HC |
Heater Error |
Replace heater |
| HP |
High Voltage
|
High power (voltage) observed. Check power connections and rerun diagnostic test |
| LB |
Light Error |
Replace underwater light bulb |
| LP |
Low Voltage
|
Low Power (voltage) observed. Check power connections and rerun diagnostic test |
| O3U |
Ozonator Error |
Replace ozonator |
| P1 |
Pump 1 Error |
Check plug for Pump 1 |
| P2 |
Pump 2 Error |
Check plug for Pump 2 |
| Pb |
Power Board
|
Check topside connection and remote panel connections to power board. |
| BUS |
Power Board Communication |
Check topside connection |
| REL |
Relay on board |
Pump relay not responding correctly |
| PS |
Pressure Switch Error |
Replace Pressure Switch or Flow Switch |
| LS |
Water Sensor |
Replace Sensor |
SS |
Heater Sensor |
Replace Sensor |
HILI |
High Limit Sensor Detects Temperature Rise Above 112F |
Allow Spa to Cool, Power Down Spa, Turn Power Back on and Reset Spa Side Control |
| FLO |
Lack of Flow:Heater disabled |
Remove filter. If “FLO”disappears, clean filter. |
| If any problems persist, call you local Vita Dealer for service. |
|